MOXA TCC-100
Industrial RS-232 to RS-422/485 converters with 2 KV isolation
- RS-232 to RS-422 conversion with RTS/CTS support
- RS-232 to 2-wire or 4-wire RS-485 conversion
- 2 kV isolation protection (TCC-100I)
- Wall and DIN-Rail mounting
- Plug-in terminal block for easy RS-422/485 wiring
- LED indicators for power, Tx, Rx
- Wide temperature model available (-40 to 85°C)
Die Modelle TCC-100 und TCC-100I sind RS-232-zu-RS-422/485-Konverter, die die Netzwerkkapazität durch Ausdehnen der RS-232-Übertragungsentfernung steigern.
Beide Konverter bieten ein modernes industrielles Design mit Hutschienen-Montage, Klemmleistenverdrahtung, externen Stromklemmleisten und optischer Isolation (nur TCC-100I). Die Modelle TCC-100/100I eignen sich ideal zur Konvertierung von RS-232-Signalen zu RS-422/485 in kritischen industriellen Umgebungen.
RS-232 Side
Connector
DB9 female
Signals
TxD, RxD, RTS, CTS, GND
RS-422/485 Side
Connector
Terminal Block
Signals
(interface selected by DIP switch)
RS-422: TxD+, TxD-, RxD+, RxD-, RTS, CTS, GND
RS-485-4w: TxD+, TxD-, RxD+, RxD-, GND
RS-485-2w: Data+, Data-, GND
RS-485 Data Direction Control
ADDC® (automatic data direction control)
Serial Communication
Baudrate
50 bps to 921.6 kbps
ESD Protection
15 kV
Optical Isolation
2 kV (TCC-100I/100I-T)
Physical Characteristics
Housing
Metal
Dimensions
67 x 100.4 x 22 mm (2.64 x 3.93 x 0.87 in)
Weight
148 ± 5 g
Environmental Limits
Operating Temperature
Standard Models: -20 to 60°C (-4 to 140°F)
Wide Temp. Models: -40 to 85°C (-40 to 185°F)
Storage Temperature
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity
5 to 95% (non-condensing)
Power Requirements
Source of Input Power
Power input jack
Input Voltage
12 to 48 VDC
Power Consumption
TCC-100/100-T: 85 mA @ 12 V
TCC-100I/100I-T: 150 mA @ 12 V
Voltage Reversal Protection
Protects against V+/V- reversal
Over Current Protection
Protects against two signals shorted together
Standards and Certifications
Safety
UL 60950-1
EMC
CE, FCC
EMI
FCC Part 15 Subpart B Class B
EMS
IEC 61000-4-2 (ESD) Level 2,
IEC 61000-4-3 (RS) Level 2,
IEC 61000-4-4 (EFT) Level 2,
IEC 61000-4-5 (Surge) Level 2,
IEC 61000-4-6 (CS) Level 2,
IEC 61000-4-8 (SFMF) Level 1
Green Product
RoHS, CRoHS, WEEE
MTBF (mean time between failures)
Time
3,017,857 hrs
Database
MIL-HDBK-217F
Ordering Information
Available Modules | |
TCC-100 | RS-232 to RS-422/485 Converter |
TCC-100I | RS-232 to RS-422/485 Converter |
TCC-100I-T | RS-232 to RS-422/485 converter with optical isolation, -40 to 85°C operating temperature |
TCC-100-T | RS-232 to RS-422/485 converter, -40 to 85°C operating temperature |
Kunden, die diesen Artikel gesehen haben, sahen auch