Raritan Branch Circuit Monitor

Data Center Panelboard and Busway Monitoring

Raritan Branch Circuit Monitor
4306_24191.png
4306_24192.png
4306_24193.png
  • EigenschaftenEigenschaften
  • BeschreibungBeschreibung
  • Weitere InformationenWeitere Informationen
  • PDFPDF
  • Meters Floor PDU, RPPs, Panelboards, and Busways.
  • One controller supports up to 70 power meters.
  • Quick configuration via USB stick preloaded with panel schedule.
  • CTs connect to live circuits.
  • Auto-correct metering adjusts for CT orientation on wires.
  • Real-time configurator.
  • USB ports for configuration, Wi-Fi networking, and tablet display.
  • Supported by DCIM software that offers auto-discovery as a panel.
  • Several enclosure options.
  • Same firmware as Raritan rack PDUs.
  • Remote display using PDView app.
  • Collects data on: A, V, kW, kVA, power factor, and kWh.
  • Protocols include TCP/IP, Modbus and SNMP.
  • Environmental sensor support
Mit dem intelligenten BCM-System (Branch Circuit Monitoring) von Raritan können Sie das volle Potenzial Ihrer Energieinfrastruktur nutzen und die Kapazitäten Ihres wachsenden und sich verändernden Rechenzentrums verwalten. Ob Sie nun eine vorhandene Anlage umrüsten oder eine neue Anlage aufbauen möchten, das BCM-System von Raritan hilft Ihnen bei der Reduzierung von Energiekosten, Nachverfolgung des Stromverbrauchs und Minimierung von Ausfallzeiten. Stellen Sie eine Zählerfunktion in Bereichen bereit, die bisher ohne auskommen mussten.

Dieses einfach bereitzustellende modulare System bietet Echtzeitansichten der elektrischen Leistung und des Stromverbrauchs an Abzweigleitungen und der Hauptleitung in einem elektrischen Service-Eingang oder einem fernen Verteilerfeld. Bei leistungs- und umgebungsbezogenen Auffälligkeiten versendet das BCM-System eine Warnmeldung, wodurch sich Ausfallzeiten vermeiden lassen. Die ermittelten Daten unterstützen Kunden bei der Umsetzung von Energieeffizienz- und Abrechnungsinitiativen. Außerdem lässt sich das BCM-System in Power IQ® DCIM Monitoring-Software sowie andere Building Management System (BMS)- und DCIM-Lösungen integrieren.
ProdGrafik

Application Part Number Description
Enclosure for monitoring panelboards — suggested for raised floor environments BCM2-9610Y-KIT-01 BCM2-9610Y-KIT-01
BCM2-9610Y (Up to 480V, 16A 3PY Terminal, 96 channel branch circuit meter enclosure with controller)
BCM2-250A-CT-4PK (4x 250A current transformer / 0.5% / 333mV / 24” / 610mm lead)
BCM2-1A-CT (1x 1A current transformer / 0.5% / 333mV / 24” / 610mm lead)
BCM2-MCTcable-3M (mains circuit cable for 5x CTs)
2x BCM2-60A-CT-12PK (12x 60A current transformer / 0.5% / 333mV / 24” / 610mm lead)
BCM2-BCTcable-3M-1, BCM2-BCTcable-3M-2, BCM2-BCTcable-3M-3, BCM2-BCTcable-3M-4 (branch circuit cables for 12x CTs each)
BCM2-FLOOR-MOUNT-KIT
DIN rail modules for monitoring panelboards BCM2-DIN-KIT-D01 PMC-1001 (rack/wall mount power meter controller)
PMM-1000 (3Phase, 480V DIN rail power meter module)
PMB-1960 (96 port power meter branch)
BCM2-250A-CT-3PK (3x250A current transformer / 0.5% / 333mV / 24” / 610mm lead)
BCM2-MCTcable-3M (mains circuit cable for 5x CTs)
2x BCM2-60A-CT-12PK (12 x 60A current transformer / 0.5% / 333mV / 24” / 610mm lead)
BCM2-BCTcable-3M-1, BCM2-BCTcable-3M-2, BCM2-BCTcable-3M-3, BCM2-BCTcable-3M-4
DIN rail modules for monitoring Busway Mains BUS-DIN-KIT-D01 PMC-1001 (rack/wall mount power meter controller)
PMM-1000 (3Phase, 480V DIN rail power meter module)
BCM2-250A-CT-3PK (3x 250A current transformer / 0.5% / 333mV / 24” / 610mm lead)
BCM2-MCTcable-0.5FT (mains circuit cable for 5x CTs)
BCM2-1A-CT (1x 1A current transformer / 0.5% / 333mV / 24” / 610mm lead)


Voltage Measurement Inputs

    Input Range*
      90–277V LN, 156–480V LL

    Measurement Category
      CAT III, Pollution Level 2

    Frequency
      50/60 Hz


Current Measurement Inputs

    CT Type
      Voltage Output = 333 mV at rated current

    CT Rated Current
      1–1200A


Power Requirements

    Voltage
      90–240V

    Current
      0.2A


Environmental

    Operating Temperature
      0°–60°C (32°-140°F)

    Operating Humidity
      5–85%

    Operating Elevation
      0-3000m


Meter Measurement Accuracy

    Active Power & Energy
      0.5%: IEC 62053 Class .5, EN 50470-3 Class C

    Reactive Power & Energy
      2%

    RMS Voltage & Current
      0.2%

    Frequency
      0.1%

    Sample Rate
      64x 50 or 60 Hz (phase locked)

    Measurement Update Rate
      3 secs: IEC 61000-4-30 Class S


Conformance

    Safety
      UL/EN 61010-1

    EMC/EMI
      EN61326-1, FCC Part 15 Class A