AKCP Current Transformers (CTXXXX)
Current Transformers are designed for easy installation with a simple, fast, safe and easy way to connect a monitoring system to your power supply
AKCess Pro Current Transformers are designed for easy installation with a simple, fast, safe and easy way to connect a monitoring system to your power supply.
AKCess Pro provide split core current transformers that can be installed without opening any cable or bus bar circuit. The connection of conventional Current Transformers (CTs) usually requires the interruption of the primary side circuit to pass cables or bus bars through the transformer core or to connect such cables to the primary terminals.
The AKCess Pro transformers core can be easily opened and installed then connected without any supply interruption. AKCess Pro Current Transformers save you time and installation costs and are safer to work with :
The AKCess Pro CTs connect to the securityProbe and has its own interface so you can set parameters for monitoring and alerting on a variety of measurement factors.
- Sensing Overload Currents
- Ground fault detection
- Metering
- Analog to Digital circuits
- Facilities and building management
AKCess Pro provide split core current transformers that can be installed without opening any cable or bus bar circuit. The connection of conventional Current Transformers (CTs) usually requires the interruption of the primary side circuit to pass cables or bus bars through the transformer core or to connect such cables to the primary terminals.
The AKCess Pro transformers core can be easily opened and installed then connected without any supply interruption. AKCess Pro Current Transformers save you time and installation costs and are safer to work with :
- Compact size for easy mounting
- Wide inner window, allowing clamping of big cables or bus bars
- Wide range of sizes to accommodate all existing installations
- High accuracy and reliability
The AKCess Pro CTs connect to the securityProbe and has its own interface so you can set parameters for monitoring and alerting on a variety of measurement factors.
Connect to AKCP securityProbe5E
The AKCP CT?s connect to the securityProbe and securityProbe 5E units. When connected to the securityProbe the unit has its own interface that allows you to set parameters for monitoring and alerting on a variety of measurement factors.
If a pre-set parameter is reached the securityProbe can trigger an alert or complete an action, e.g. Email, SMS, MMS, Fax, Switch/Relay or even make a Telephone call.
These CT?s connect to the ?CT? type AKCP Power Monitor Sensor which in turn then connects to the AKCP securityProbe unit.
Specifications
Primary current :
Secondary current :
Standard approval :
Maximum voltage :
Frequency :
Rated load :
Class :
Short-time thermal current :
Rated security coefficient :
Ordering Information
The AKCP CT?s connect to the securityProbe and securityProbe 5E units. When connected to the securityProbe the unit has its own interface that allows you to set parameters for monitoring and alerting on a variety of measurement factors.
If a pre-set parameter is reached the securityProbe can trigger an alert or complete an action, e.g. Email, SMS, MMS, Fax, Switch/Relay or even make a Telephone call.
These CT?s connect to the ?CT? type AKCP Power Monitor Sensor which in turn then connects to the AKCP securityProbe unit.
Specifications
Primary current :
- 100A-5000A
Secondary current :
- 5A, 1A
Standard approval :
- IEC44-1, BS7626
Maximum voltage :
- 0.72/3Kv
Frequency :
- 50/60Hz
Rated load :
- 1VA-30VA
Class :
- 0.5, 1.0, 3.0
Short-time thermal current :
- 1th=100xln
Rated security coefficient :
- FS<5
Ordering Information
Product Model | Order Number | Description |
---|---|---|
Split Core Current Transformer (CT only not including meter) | ||
CTXXX/5A | From 100/5A to 400/5A | |
CTXXX/5A | From 500/5A to 800/5A | |
CTXXX/5A | From 1000/5A to 4000/5A | |
Split Core Current Transformer (With 0-5VDC Output for use with A2D) | ||
CTXXX/5V | From 5A/5V to 50A/5V | |
CTXXX/5V | From 10A/5V to 100A/5V | |
CTXXX/5V | From 100A/5V to 300A/5V | |
CTXXX/5V | From 100A/5V to 500A/5V | |
Note: XXX is number of Amps required |