AKCP Dry Contact Cable (DCSxx)
(dry contact on sensor port)
Ability to have up to 5 dry contact inputs per RJ45 on the SP2
- Optional 5 / max 10 dry contacts on sensorProbe2DC
- Normally open/normally closed dry contact sensor
- Input mode Only
- Input voltage range 0-5 Volts
An optional feature of the sensorProbe2DC is the ability to have up to 5 dry contact inputs per RJ45. This gives a total maximum possible inputs of 10 per sensorProbe2DC by utilizing both of the RJ45 sensor ports.
These dry-contact ports can be used to monitor any dry-contact inputs, just like the normal autosense dry-contact ports, but, these ports can only be set to operate in the input mode.These additional sensors are labeled as ports 3 to 12.
The single port RJ-45 Dry Contact Sensor with an ALARM/NORMAL indication in the software.
Can have up two on a sensorProbe2, eight on a sensorProbe8 and 600 Dry Contact Sensors on a secuirtyProbe unit.
Dry contact sensors are user denable and can be used to detect many dierent inputs such as UPS status, security systems, air conditioning status.
SNMP interface for alarm/normal status.
SNMP traps can be sent when the sensor is in a critical state.
SNMP polling is possible via SNMPget. Web browser interface is available.
When an alarm condition is activated the description and location of the fault can be sent via an email or SNMP trap.
These dry-contact ports can be used to monitor any dry-contact inputs, just like the normal autosense dry-contact ports, but, these ports can only be set to operate in the input mode.These additional sensors are labeled as ports 3 to 12.
The single port RJ-45 Dry Contact Sensor with an ALARM/NORMAL indication in the software.
Can have up two on a sensorProbe2, eight on a sensorProbe8 and 600 Dry Contact Sensors on a secuirtyProbe unit.
Dry contact sensors are user denable and can be used to detect many dierent inputs such as UPS status, security systems, air conditioning status.
SNMP interface for alarm/normal status.
SNMP traps can be sent when the sensor is in a critical state.
SNMP polling is possible via SNMPget. Web browser interface is available.
When an alarm condition is activated the description and location of the fault can be sent via an email or SNMP trap.
Specifications
Measurement Range :
- Alarm or Normal
Communications cable :
- RJ-45 jack to sensor using UTP Cat 5 wire
Sensor Type :
- Open / Closed contact switch
Input Voltage Range :
- 0 to 5 volts
Power Source :
- Powered by the sensorProbe. No additional power needed
Measurement Rate :
- Multiple readings every second
- Normal input voltage is settable under software
- Normally open, normally closed is settable under software
- Up to 5 dry contact inputs per RJ-45 making upto 10 Dry Contact Inputs in sensorProbe2
Product Code:
DCS15
Ordering Information
Product Model | Order Number | Descrition |
---|---|---|
Dry Contact Cable (dry contact on sensor port) | ||
DCS15 | 949022 | 15ft Dry Contact Cable |
DCS60 | 60ft Dry Contact Cable | |
DCS100 | 100ft Dry Contact Cable |