MOXA ioLogik E2212
Active Ethernet I/O Server with 8 DI, 8 DO, and 4 DIO
![MOXA ioLogik E2212](https://www.sphinxcomputer.de/produktdb/images/products/1670_12200.png)
![1670_12200.png](https://www.sphinxcomputer.de/produktdb/images/products/1670_12200.png)
![1670_8577.png](https://www.sphinxcomputer.de/produktdb/images/products/1670_8577.png)
![1670_12201.jpg](https://www.sphinxcomputer.de/produktdb/images/products/1670_12201.jpg)
- Active communication with patented Active OPC Server
- Smart Alarm management with email, SNMP Trap, TCP, UDP
- Supports SNMPv1/v2c/v3 protocol
- Save time and wiring costs with peer-to-peer communication
- Front-end intelligent with patented Click&Go control logic, up to 24 rules
- Friendly configuration with web browser
Flexible digital input/output configuration within one Ethernet DIO
The MOXA ioLogik E2212 provides system integrators with the flexibility to handle various field demands with 8 fixed input channels, 8 fixed output channels, and 4 channels that can be configured by software for input or output operation. You can configure the I/O channels to suit your needs, for combinations such as 12 inputs/8 outputs, 8 inputs/12 outputs or 10 inputs/10 outputs.
Single Ethernet DIO that accepts 3 types of sensors
Unlike traditional Ethernet I/O products, the MOXA ioLogik E2212 can connect to dry contact, PNP, and NPN sensors at the same time. You may decide on the sensor type depending on your wiring approach.![ProdGrafik](https://www.sphinxcomputer.de/produktdb/images/products/1670_8577.png)
The MOXA ioLogik E2212 provides system integrators with the flexibility to handle various field demands with 8 fixed input channels, 8 fixed output channels, and 4 channels that can be configured by software for input or output operation. You can configure the I/O channels to suit your needs, for combinations such as 12 inputs/8 outputs, 8 inputs/12 outputs or 10 inputs/10 outputs.
Single Ethernet DIO that accepts 3 types of sensors
Unlike traditional Ethernet I/O products, the MOXA ioLogik E2212 can connect to dry contact, PNP, and NPN sensors at the same time. You may decide on the sensor type depending on your wiring approach.
![ProdGrafik](https://www.sphinxcomputer.de/produktdb/images/products/1670_8577.png)
ioLogik E2212 Specifications
Inputs and Outputs
Digital Inputs
8 channels
Digital Outputs
8 channels
Configurable DI/Os
4 channels
Isolation
3k VDC or 2k Vrms
Digital Input
Sensor Type
Wet Contact (NPN or PNP) and Dry Contact
I/O Mode
DI or Event Counter
Dry Contact
- On: short to GND
- Off: open
Wet Contact (DI to GND)
- On: 0 to 3 VDC
- OFF: 10 to 30 VDC
Common Type
6 points per COM
Counter Frequency
900 Hz
Digital Filtering Time Interval
Software Configurable
Digital Output
Type
Sink
I/O Mode
DO or Pulse Output
Pulse Output Frequency
1 kHz
Over-voltage Protection
45 VDC
Over-current Protection
2.6 A (4 channels @650 mA)
Over-temperature Shutdown
175°C (min.)
Current Rating
200 mA per channel
Power Requirements
Power Consumption
136 mA @ 24 VDC
MTBF (mean time between failures)
Time
217,722 hrs
Database
Telcordia (Bellcore)
Common Specifications
LAN
Ethernet
1 10/100 Mbps RJ45 port
Protection
1.5 kV magnetic isolation
Protocols
Modbus/TCP, TCP/IP, UDP, DHCP, BOOTP, SNMP, HTTP, CGI, SNTP, SMTP
Serial Communication
Interface
RS-485-2w: Data+, Data-, GND (3-contact terminal block)
Serial Line Protection
15 kV ESD for all signals
Serial Communication Parameters
Parity
None
Data Bits
8
Stop Bits
1
Flow Control
None
Baudrate
1200 to 115200 bps
Protocol
Modbus/RTU
Power Requirements
Power Input
24 VDC nominal, 12 to 36 VDC
Physical Characteristics
Wiring
I/O cable max. 14 AWG
Dimensions
115 x 79 x 45.6 mm (4.53 x 3.11 x 1.80 in)
Weight
under 250 g
Mounting
DIN rail or wall
Environmental Limits
Operating Temperature
Standard Models: -10 to 60°C (14 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity
5 to 95% (non-condensing)
Altitude
Up to 2000 m
Note Please contact us if you require products guaranteed to function properly at higher altitudes.
Standards and Certifications
Safety
UL 508
EMI
EN 61000-3-2; EN 61000-3-3; EN 61000-6-4;
FCC
Part 15, Subpart B, Class A
EMS
EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5,
EN 61000-4-6, EN 61000-4-8, EN 61000-4-11, EN 61000-6-2
Shock
IEC 60068-2-27
Freefall
IEC 60068-2-32
Vibration
IEC 60068-2-6
Green Product
RoHS, CRoHS, WEEE
Ordering Information
Available Modules | |
ioLogik E2212 | Ethernet Micro RTU Controller with 8 digital inputs, 8 digital outputs, and 4 configurable DIOs |
ioLogik E2212-T | Ethernet Micro RTU Controller with 8 digital inputs, 8 digital outputs, and 4 configurable DIOs, -40 to 85°C operating temperature |
![](images/Layout/Weitere-Informationen_weiss.png)